- Tissue
- Breast
- Disease
- Malignant neoplasms of the mouse mammary gland
- Synonyms
- EMT-6, Experimental Mammary Tumour-6
Documents
EMT6
Cell line · Product number 305159
The EMT6 cell line is a murine mammary adenocarcinoma line that is extensively used in cancer research, particularly in studies related to breast cancer. ...
Customization / Recommendations
- EMT6Cell line€430.00
Recommended (freshest lot)
01General information
- Description
The EMT6 cell line is a murine mammary adenocarcinoma line that is extensively used in cancer research, particularly in studies related to breast cancer. Originating from a spontaneous tumor in a BALB/c mouse, EMT6 cells are employed both in vitro and in vivo to analyze tumorigenesis, metastasis, and chemotherapeutic resistance. The cells are characterized by their ability to form tumors rapidly when transplanted into immunocompetent mice, making them an ideal model for studying tumor immunity and the efficacy of anti-cancer therapies.
EMT6 cells are highly adaptable to various growth conditions and have a relatively high mitotic index, which facilitates easy cultivation and experimental manipulation in laboratory settings. They are also used in radiobiology studies due to their pronounced sensitivity to radiation, providing insights into the cellular mechanisms underlying radiation therapy for cancer. The cell line has been instrumental in the development of protocols for hypoxic cell sensitizers and has been used to test the efficacy of photodynamic therapy agents.
- Tissue
- Breast
- Disease
- Malignant neoplasms of the mouse mammary gland
- Synonyms
- EMT-6
- Experimental Mammary Tumour-6
02Classification
- Organism
- Mouse
- Sex
- Female
- Growth properties
- Adherent
- Biosafety level
- 1
03Characteristics
- Morphology
- Epithelial
04Identifiers
- Citation
- EMT6 (Cytion catalog number 305159)
- NCBI TaxID
- 10090
- Cellosaurus
- CVCL_1923
05Handling and culture
- Culture medium
- DMEM:Ham's F12 (1:1), w: 3.1 g/L Glucose, w: 2.5 mM L-Glutamine, w: 15 mM HEPES, w: 0.5 mM Sodium pyruvate, w: 1.2 g/L NaHCO3 (Cytion article number 820400a)
- Incubation atmosphere
37°C, 5% CO2, humidified atmosphere.
- Supplements
- Supplement the medium with 10% FBS
- Dissociation reagent
- Accutase
- Subculturing
- Remove the old medium from the adherent cells and wash them with PBS that lacks calcium and magnesium. For T25 flasks, use 3-5 ml of PBS, and for T75 flasks, use 5-10 ml. Then, cover the cells completely with Accutase, using 1-2 ml for T25 flasks and 2.5 ml for T75 flasks. Let the cells incubate at room temperature for 8-10 minutes to detach them. After incubation, gently mix the cells with 10 ml of medium to resuspend them, then centrifuge at 300xg for 3 minutes. Discard the supernatant, resuspend the cells in fresh medium, and transfer them into new flasks that already contain fresh medium.
- Fluid renewal
- 2 to 3 times per week
- Thawing and culturing
Confirm that the vial remains deeply frozen upon delivery, as cells are shipped on dry ice to maintain optimal temperatures during transit.
Upon receipt, either store the cryovial immediately at temperatures below -150°C to ensure the preservation of cellular integrity, or proceed to step 3 if immediate culturing is required.
For immediate culturing, swiftly thaw the vial by immersing it in a 37°C water bath with clean water and an antimicrobial agent, agitating gently for 40-60 seconds until a small ice clump remains.
Perform all subsequent steps under sterile conditions in a flow hood, disinfecting the cryovial with 70% ethanol before opening.
Carefully open the disinfected vial and transfer the cell suspension into a 15 ml centrifuge tube containing 8 ml of room-temperature culture medium, mixing gently.
Centrifuge the mixture at 300 x g for 3 minutes to separate the cells and carefully discard the supernatant containing residual freezing medium.
Gently resuspend the cell pellet in 10 ml of fresh culture medium. For adherent cells, divide the suspension between two T25 culture flasks; for suspension cultures, transfer all the medium into one T25 flask to promote effective cell interaction and growth.
Adhere to established subculture protocols for continued growth and maintenance of the cell line, ensuring reliable experimental outcomes.
06Quality control and cryopreservation
- Sterility
Mycoplasma contamination is excluded using both PCR-based assays and luminescence-based mycoplasma detection methods.
To ensure there is no bacterial, fungal, or yeast contamination, cell cultures are subjected to daily visual inspections.
- Freeze medium
- As a cryopreservation medium, we use complete growth medium (including FBS) + 10% DMSO for adequate post-thaw viability, or CM-1 (Cytion catalog number 800100), which includes optimized osmoprotectants and metabolic stabilizers to enhance recovery and reduce cryo-induced stress.
- Storage conditions
For long-term preservation, place vials in vapor-phase liquid nitrogen at about −150 to −196 °C. Storage at −80 °C is acceptable only as a short interim step before transfer to liquid nitrogen.
- Shipping conditions
Cryopreserved cell lines are shipped on dry ice in validated, insulated packaging with sufficient refrigerant to maintain approximately −78 °C throughout transit. On receipt, inspect the container immediately and transfer vials without delay to appropriate storage.
07Donor
- Breed / subspecies
- BALB/cCRGL
08Legal and safety
- Safety precautions
- When planning to store a cryovial in liquid nitrogen for future thawing, it is mandatory to adhere to stringent safety measures. Appropriate protective gloves and clothing are essential, and the use of a face mask or safety goggles is required during the transfer of frozen samples to or from the liquid nitrogen tank. This is to mitigate the risk of injury from potential cryovial explosions upon removal, which can result in the projection of sharp fragments.
- Warranty
At Cytion, we stand behind the quality and viability of our products. We guarantee that our cells will be viable at the start of culture for 60 days after shipment from our facilities. We assure that all materials conform to the specifications described in the Certificate of Analysis and/or Product Sheet.
For full details, please refer to our Warranty Statement.
- Material Transfer Agreement required
- Yes