MA-104
Cell line · Product number 305007
The MA-104 cell line is derived from rhesus monkey kidney epithelial cells and is widely used in virology and vaccine production research. These cells exh...
Customization / Recommendations
- MA-104Cell line€550.00
Recommended (freshest lot)
01General information
- Description
The MA-104 cell line is derived from rhesus monkey kidney epithelial cells and is widely used in virology and vaccine production research. These cells exhibit a typical epithelial morphology, adhering tightly to the substrate and forming a monolayer. Due to their origin, MA-104 cells are particularly permissive to the replication of various viruses, including rotaviruses, polioviruses, and reoviruses, making them an essential tool in virological studies, especially in the propagation and isolation of these pathogens. Their high susceptibility to viral infection allows for efficient viral growth, which is crucial for vaccine development and testing.
In addition to their role in virology, MA-104 cells are also employed in studies focusing on cell biology and physiology, particularly those investigating kidney function and epithelial cell behavior. These cells have been instrumental in understanding the mechanisms of viral entry, replication, and the host-cell response to infection. Researchers also utilize MA-104 cells to study protein expression and post-translational modifications due to their ability to support high levels of protein production.
- Tissue
- Kidney
- Synonyms
- Ma-104
- MA 104
- MA104
- Microbiological Associates-104
02Classification
- Organism
- Vervet monkey
- Growth properties
- Adherent
- Biosafety level
- 1
03Characteristics
- Morphology
- Epithelial
04Identifiers
- Citation
- MA-104 (Cytion catalog number 305007)
- NCBI TaxID
- 60710
- Cellosaurus
- CVCL_3845
05Handling and culture
- Culture medium
- EMEM (MEM Eagle), w: 2 mM L-Glutamine, w: 2.2 g/L NaHCO3, w: EBSS (Cytion article number 820100a)
- Incubation atmosphere
37°C, 5% CO2, humidified atmosphere.
- Supplements
- Supplement the medium with 10% FBS and 1% NEAA
- Dissociation reagent
- Accutase
- Subculturing
- Remove the old medium from the adherent cells and wash them with PBS that lacks calcium and magnesium. For T25 flasks, use 3-5 ml of PBS, and for T75 flasks, use 5-10 ml. Then, cover the cells completely with Accutase, using 1-2 ml for T25 flasks and 2.5 ml for T75 flasks. Let the cells incubate at room temperature for 8-10 minutes to detach them. After incubation, gently mix the cells with 10 ml of medium to resuspend them, then centrifuge at 300xg for 3 minutes. Discard the supernatant, resuspend the cells in fresh medium, and transfer them into new flasks that already contain fresh medium.
- Fluid renewal
- 2 to 3 times per week
- Thawing and culturing
Confirm that the vial remains deeply frozen upon delivery, as cells are shipped on dry ice to maintain optimal temperatures during transit.
Upon receipt, either store the cryovial immediately at temperatures below -150°C to ensure the preservation of cellular integrity, or proceed to step 3 if immediate culturing is required.
For immediate culturing, swiftly thaw the vial by immersing it in a 37°C water bath with clean water and an antimicrobial agent, agitating gently for 40-60 seconds until a small ice clump remains.
Perform all subsequent steps under sterile conditions in a flow hood, disinfecting the cryovial with 70% ethanol before opening.
Carefully open the disinfected vial and transfer the cell suspension into a 15 ml centrifuge tube containing 8 ml of room-temperature culture medium, mixing gently.
Centrifuge the mixture at 300 x g for 3 minutes to separate the cells and carefully discard the supernatant containing residual freezing medium.
Gently resuspend the cell pellet in 10 ml of fresh culture medium. For adherent cells, divide the suspension between two T25 culture flasks; for suspension cultures, transfer all the medium into one T25 flask to promote effective cell interaction and growth.
Adhere to established subculture protocols for continued growth and maintenance of the cell line, ensuring reliable experimental outcomes.
06Quality control and cryopreservation
- Sterility
Mycoplasma contamination is excluded using both PCR-based assays and luminescence-based mycoplasma detection methods.
To ensure there is no bacterial, fungal, or yeast contamination, cell cultures are subjected to daily visual inspections.
- Freeze medium
- As a cryopreservation medium, we use complete growth medium (including FBS) + 10% DMSO for adequate post-thaw viability, or CM-1 (Cytion catalog number 800100), which includes optimized osmoprotectants and metabolic stabilizers to enhance recovery and reduce cryo-induced stress.
- Storage conditions
For long-term preservation, place vials in vapor-phase liquid nitrogen at about −150 to −196 °C. Storage at −80 °C is acceptable only as a short interim step before transfer to liquid nitrogen.
- Shipping conditions
Cryopreserved cell lines are shipped on dry ice in validated, insulated packaging with sufficient refrigerant to maintain approximately −78 °C throughout transit. On receipt, inspect the container immediately and transfer vials without delay to appropriate storage.
07Donor
- Donor age
- Fetus
08Legal and safety
- Safety precautions
- When planning to store a cryovial in liquid nitrogen for future thawing, it is mandatory to adhere to stringent safety measures. Appropriate protective gloves and clothing are essential, and the use of a face mask or safety goggles is required during the transfer of frozen samples to or from the liquid nitrogen tank. This is to mitigate the risk of injury from potential cryovial explosions upon removal, which can result in the projection of sharp fragments.
- Warranty
At Cytion, we stand behind the quality and viability of our products. We guarantee that our cells will be viable at the start of culture for 60 days after shipment from our facilities. We assure that all materials conform to the specifications described in the Certificate of Analysis and/or Product Sheet.
For full details, please refer to our Warranty Statement.
- Material Transfer Agreement required
- Yes